No-Load Check
Run engine from idling up to 2000 rpm and read meters.
NOTE:
Turn off switches of all accessories (wiper, heater etc.).
Specification for undercharged inspection
Current: 10 A maximum
Voltage (at 20 °C (68 °F)): 14.2 - 14.8 V
NOTE:
Consideration should be taken that voltage will differ somewhat with regulator case temperature as shown in the figure.
- If voltage is higher than standard value
If voltage is higher than standard value, check ground of brushes.
If brushes are not grounded, replace IC regulator.
- If voltage is below or in standard value
If voltage is lower than standard value, proceed to the following check.
- Ground "F" terminal and start engine, then measure voltage at "B" terminal as shown in the figure.
Voltage is higher than standard value:
- It is considered that generator itself is good but IC regulator has been damaged, replace IC regulator.
Voltage is lower than standard value:
- Generator itself has problem, check the generator.