LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2006 >> XL-7 Base, 4WD, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater And Ventilation >> Repair Instructions >> Blower Motor Controller Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Blower Motor Controller Inspection

Reference: BLOWER MOTOR CONTROLLER REMOVAL AND INSTALLATION 

Measure each terminal-to-terminal resistance on blower motor controller.

If measured resistance is incorrect, replace blower motor controller with new one.

BLOWER MOTOR CONTROLLER RESISTANCE

Terminal Resistance (kΩ)
+ Wire - Wire
4 2 Continuity
4 3 Approx. 10.18
2 4 No continuity
2 3 No continuity
3 4 Approx. 10.18
3 2 Continuity
Fig 1: Checking Blower Motor Controller Resistance
G04723274Courtesy of SUZUKI OF AMERICA CORP.