Keyless Entry Receiver and Its Circuit Inspection: Notes
Check that the voltage between the following terminals and body ground are specifications under each conditions. If check result is not as specified, check applicable circuit for open or short. If circuit is normal, recheck keyless entry receiver (1) as follows.
- Substitute a known-good keyless entry receiver.
- Record key code referring to PROGRAMMING TRANSMITTER CODE .
- Recheck keyless entry receiver system.