EVAP Canister Vent Valve Circuit Check
- Connect SUZUKI scan tool (1) to DLC (2) with ignition switch turned OFF.
- Turn ignition switch to ON position, clear DTC and select "MISC TEST" mode on SUZUKI scan tool.
- Check that operating sound of EVAP canister vent valve (3) is heard only when EVAP canister vent valve is switched ON and OFF using SUZUKI scan tool. If operating sound of EVAP canister vent valve is not heard, check EVAP canister vent valve, wire harness and connections.