Body Electrical Control System Check
TEST PROCEDURE - BODY ELECTRICAL CONTROL SYSTEM CHECK
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | Was "Customer complaint analysis" performed? | Go to Step 2. | Perform "Customer complaint analysis". |
| 2 |
Does "Clock/Temp. display" come ON or keep flashing? |
Go to Step 3. | Proceed to Step 1 from Step 3 of BCM POWER CIRCUIT AND GROUND CIRCUIT CHECK . If OK, substitute a known-good BCM and recheck. |
| 3 |
Is it malfunction code? |
Go to Step 4. | Go to Step 5. |
| 4 |
Does trouble occur? |
Go to Step 3. | Go to Step 7. |
| 5 |
Is trouble symptom identified? |
Go to its system symptom diagnosis flow. | Go to Step 6. |
| 6 |
Is it in good condition? |
Substitute a known-good BCM and recheck. | Go to Step 7. |
| 7 |
Does trouble recur? |
Go to Step 3. | BCM is in good condition. |