LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2006 >> XL-7 2WD V6-2.7L >> Repair and Diagnosis >> Starting and Charging >> Charging System >> Alternator >> Service and Repair >> Dismounting and Remounting
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Dismounting and Remounting

Dismounting
1. Disconnect negative (-) cable at battery.
2. Disconnect generator lead wire ("B" terminal wire) and coupler from generator.
3. Remove generator belt. Refer to "Cooling Fan / Generator Belt Removal and Installation:".
4. Remove generator drive belt adjusting bolt and generator mounting bolt.
5. Remove generator.




Remounting
1. Mount generator on the generator bracket.
2. Tighten generator bolts (upper bolt (short) (1), lower bolt (long) (2)).

Tightening torque
Generator mounting bolt (a): 23 N.m (2.3 kg-m, 17.0 lb-ft)

3. Install generator (cooling fan) belt. Refer to "Cooling Fan / Generator Belt Removal and Installation:".
4. Connect "B" terminal wire (3) and coupler to generator.

Tightening torque
"B" terminal outer nut (b): 8 N.m (0.8 kg-m, 6.0 lb-ft)

5. Install canister.
6. Connect negative (-) cable at battery.