Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 2. Tests for the normal state of the window switch using a scan tool. The scan tool will display the normal state as Inactive, and Active when the switch is activated.
- 3. Tests if the ISU is able to detect a change in window switch state. The scan tool will display the normal state as Inactive, and Active when the switch is activated.
- 4. Tests for a stuck or shorted window switch. If the window switch is stuck or shorted, the state will change from Active to Inactive when the window switch is disconnected.
- 5. Tests for a short to ground in the window switch signal circuit.