Blower Motor Inspection
WARNING: This page is about a different car, the 2006 Suzuki XL-7. However, it is still accessible from the selected car via links, so may be relevant.
Reference: BLOWER MOTOR REMOVAL AND INSTALLATION
- Check continuity between terminal to terminal as shown in figure.
If check results are continuity, proceed to next operation check. If not, replace.
- Connect battery to blower motor as shown, then check if the blower motor operates smoothly.
Reference specified consumption current for blower motor
18 - 24 A at 12 V