Fuel Level Sensor Rationality Monitor
WARNING: This page is about a different car, the 2006 Suzuki XL-7. However, it is still accessible from the selected car via links, so may be relevant.
Operation
FUEL LEVEL SENSOR RATIONALITY MONITOR OPERATION
| DTCs | P0461 |
| Monitor execution | Every 5 L fuel consumption |
| Monitoring Duration | |
| Sensors / components OK | IAT, ECT, Barometric pressure |
Enable conditions
FUEL LEVEL SENSOR RATIONALITY MONITOR ENABLE CONDITIONS
| Parameter | Minimum | Maximum |
|---|---|---|
| Fuel consumption accumulation | 5 L | |
| Time from engine start | 2.5 s | |
| Engine coolant temp. | -8 (17) °C (°F) | 110 (230) °C (°F) |
| IAT | -8 (17) °C (°F) | |
| Barometric pressure | 74.5 kPa |
Typical malfunction thresholds
FUEL LEVEL SENSOR RATIONALITY MONITOR TYPICAL MALFUNCTION THRESHOLDS
| Fuel level change < 4% |