Sensor Circuit Monitor
WARNING: This page is about a different car, the 2006 Suzuki XL-7. However, it is still accessible from the selected car via links, so may be relevant.
Operation
SENSOR CIRCUIT MONITOR OPERATION
| DTCs | P0102 / P0103, P0107 / P0108, P0112 / P0113, P0117 / P0118, P0122 / P0123, P0327 / P0328, P0462 / P0463, P2228 / P2229 |
| Monitor execution | Continuous |
| Sensors OK | - |
| Monitoring Duration | 5 s |
Enable conditions
SENSOR CIRCUIT MONITOR ENABLE CONDITIONS
| Parameter | Minimum | Maximum |
|---|---|---|
| P0462 | ||
| Battery voltage | 11 V | |
| P0463 | ||
| Battery voltage | 15.4 V | |
Typical malfunction thresholds
SENSOR CIRCUIT MONITOR TYPICAL MALFUNCTION THRESHOLDS
| P0102: Sensor voltage < 0.6 V |
| P0103: Sensor voltage > 4.9 V |
| PP0107: Voltage < 0.2 V |
| P0108: Voltage ≥ 4.8 V |
| P0112: IAT < 0.3 V (120 (248) °C (°F)) |
| P0113: IAT > 4.6 V (-48 (-54) °C (°F)) |
| P0117: IAT < 0.2 V (134 (273) °C (°F)) |
| P0118: IAT > 4.6 V (-49 (-56) °C (°F)) |
| P0122: TP < 0.2 V (3.9 °(0.156 V)) |
| P0123: TP > 4.8 V (119.1 °(4.77 V)) |
| P0327: Min. voltage < 0.9 V |
| P0328: Max. voltage > 4.0 V |
| P0462: Sensor output voltage < 0.2 V |
| P0463: Sensor output voltage ≥ 8.6 V |
| P2228: Voltage < 0.5 V (43 kPa) |
| P2229: Voltage > 4.24 V (112 kPa) |