Typical Scan Tool Data
Rough Road Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine operating in Closed Loop Parameter Normal Range: 1.1-3.7 Volts |
|||
| 5-Volt Reference | 0.0 Volts | 0.0 Volts | 5.0 Volts1 |
| Rough Road Sensor Signal | 0.0 Volts | 0.0 Volts | 5.0 Volts1 |
| Low Reference | - | 0.0 Volts | 5.0 Volts1 |
| 1 Internal ECM damage may occur if the circuit is shorted to B+. | |||