Component Testing
- Measure for 40-80 ohms of resistance between the following terminals of the IAC valve.
- A and B
- C and D
- If the resistance is not within the specified range, replace the IAC valve.
- Test for infinite resistance between the following terminals of the IAC valve.
- A and C
- B and C
- If less than infinite resistance, replace the IAC valve.
- Test for infinite resistance between each terminal of the IAC valve, and the housing of the IAC valve.
- If less than infinite resistance, replace the IAC valve.