Starter Motor Disassembly and Assembly: Assembly
- Install the drive and the pinion stop on the driveshaft.
See Figure.
- Install the lock ring into the groove on the driveshaft and insert the collar.
See Figure.
- Install the shift lever, washer and the cushion.
See Figure.
- Lubricate the drive end of the armature shaft with lubricant.
See Figure.
- Position the solenoid assembly.
See Figure.
- Fasten the solenoid assembly with the screws.
Tighten:
Tighten the starter solenoid assembly screws to 8 N.m (71 lb-in).
- Install the field coil connection to the starter terminal. Install the nut.
Tighten:
Tighten the starter field coil connector nut to 8 N.m (71 lb-in).
See Figure
- Position the armature assembly into the field frame.
- Place the shield on the armature and field frame assembly.
- Install the armature and field frame assembly with the shield into the starter housing.
See Figure.
- Position the commutator end frame/brush holder assembly, lining up the end frame holes with the through-bolt holes in the housing.
See Figure.
- Install the starter through-bolts.
- Install the starter. Refer to Starter Removal and Installation .
Tighten:
Tighten the starter through-bolts to 6 N.m (53 lb-in).
See Figure.