LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2006 >> Reno Base, Automatic >> Repair and Diagnosis (Single Page) >> Engine Performance >> Testing & Diagnosis >> Engine Performance - DTC P0016 - P0141 >> DTC P0139: HO2S Slow Response Sensor 2 >> Circuit Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit Description

The Engine Control Module (ECM) supplies a voltage of about 0.45 V between the ECM terminals C62 and C4. The Heated Oxygen (HO2) sensor varies the voltage within a range of about 1 V if the exhaust is rich, down to about 0.1 V if the exhaust is lean. The HO2 sensor is like an open circuit and produces no voltage when it is below 360 °C (600 °F). An open HO2 sensor circuit or a cold HO2 sensor causes "Open Loop" operation.