Using Monitor Connector (If Equipped)
- Turn ignition switch to ON position and wait about 6 seconds or more.
- Using service wire (4), repeat shorting and opening between diagnosis switch terminal (3) on "AIR BAG" monitor coupler (1) and body ground (2) 5 times at about 1 second intervals within 10 seconds.
- Perform DTC Check and confirm that normal DTC (NO. 0000) is displayed and not malfunction DTC.NOTE: If DTC B1013 or B1021 is stored in SDM, it is not possible to clear all DTC.