Home >> Suzuki >> 2006 >> Grand Vitara Premium, RWD, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> Diagnostic Information And Procedures >> Abnormal Noise Symptom Diagnosis Of A/C System >> Abnormal Noise from Magnetic Clutch
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Abnormal Noise from Magnetic Clutch

ABNORMAL NOISE SYMPTOM DIAGNOSIS OF A/C SYSTEM - MAGNETIC CLUTCH

Condition Possible Cause Action
A rumbling noise is heard when compressor is not in operation  Worn or damaged bearings Replace magnet clutch assembly  .
A chattering noise is heard when compressor is in operation  Faulty magnet clutch clearance (excessive clearance) Adjust magnet clutch clearance  .
Worn magnet clutch friction surface Replace magnet clutch assembly  .
Compressor oil leaked from shaft seal, contaminating the friction surface Replace compressor body assembly  .