Reference Waveform No. 7
WARNING: This page is about a different variant/trim than selected.
Input shaft speed sensor signal at engine idling
TERMINALS REFERENCE CHART
| Measurement terminal |
CH1: E93-6 to E92-1 |
| Oscilloscope setting |
CH1: 5 V/DIV TIME: 2 ms/DIV |
| Measurement condition |
- After warmed up to normal operating temperature
- Engine at idling speed (700 r/min.)
|