No-Load Check
- Run engine from idling up to 2000 RPM and read meters.NOTE: Turn off switches of all accessories (wiper, heater etc.).
Specification for undercharged inspection
Current: 10 A
Voltage (at 20 °C (68 °F)): 14.2-14.8 V
NOTE: Consideration should be taken that voltage will differ somewhat with regulator case temperature as shown in the figure.
- If voltage is higher than standard value
If voltage is higher than standard value, check ground of brushes.
If brushes are not grounded, replace IC regulator.
- If voltage is lower than standard value
If voltage is lower than standard value, check rotor and stator, rectifier, brushes, regulator.