Yaw Rate/G Sensor Assembly Removal And Installation: Installation
Reference: YAW RATE/G SENSOR INSPECTION
- Before installing yaw rate/G sensor assembly (1), check installing condition as follows.
- Deformations around sensor installation area (2) (in floor panel).
- Foreign matters on mating surface between sensor and floor panel.
- Install yaw rate/G sensor assembly (1) to floor panel.
Tightening torque
Yaw rate/G sensor assembly bolt a: 8 N.m (0.8 kg-m, 6.0 lb-ft)
- Install console rear panel referring to CONSOLE BOX COMPONENTS .
- Connect negative (-) cable to battery.
- After completing installation, calibrate yaw rate/G sensor assembly referring to SENSOR CALIBRATION .