Information Display Symptom Diagnosis (If Equipped)

NOTE: This thermometer indicates the ambient temperature in back of front bumper member. Under any one of the following listed conditions, however, even when the ambient temperature goes up, the thermometer display does not rise so as to correct the rise of the ambient temperature caused by the radiant heat of the engine. When the ambient temperature drops, the thermometer reading follows the change in the temperature.
Be sure to bear this in mind when diagnosing trouble.
  • The vehicle speed is 30 km/h (18 mph) or lower.
  • VSS signal is faulty.
  • The ignition switch is turned on again within 2 hours.
INFORMATION DISPLAY SYMPTOM DIAGNOSIS

Condition Possible Cause Action
No displaying of information display  Circuit fuse Blown Replace fuse and check for short circuit  .
Wiring and/or grounding faulty Repair as necessary  .
Information display unit faulty Replace unit  .
Incorrect thermometer display  Outside air temperature sensor faulty Check outside air temperature sensor referring to OUTSIDE AIR TEMPERATURE SENSOR INSPECTION (IF EQUIPPED) .
Vehicle speed signal faulty Check ECM for DTC referring to DTC CHECK .
Wiring and/or grounding faulty Repair as necessary  .
BCM faulty Replace after making sure that none of above parts is faulty  .
Display does not change at -30 °C (-22 °F)  Outside air temperature is -30 °C (-22 ° F) or less -
Outside air temperature sensor faulty Check outside air temperature sensor referring to OUTSIDE AIR TEMPERATURE SENSOR INSPECTION (IF EQUIPPED) .
Outside air temperature sensor wiring circuit open circuit and/or short to power circuit Repair as necessary  .
BCM faulty Replace after making sure that none of above parts is faulty  .
Display does not change at 50 ° C (122 °F)  Outside air temperature is 50 °C (122 ° F) or more -
Outside air temperature sensor faulty Check outside air temperature sensor referring to OUTSIDE AIR TEMPERATURE SENSOR INSPECTION (IF EQUIPPED) .
Outside air temperature sensor wiring circuit short to ground circuit Repair as necessary  .
BCM faulty Replace after making sure that none of above parts is faulty  .