Oil Cooler Pipes Removal And Installation: Installation

  1. Use new union gaskets and connect oil cooler pipes to oil outlet unions.
  2. Connect hoses to pipes and clamp them securely.
  3. Tighten union bolts (2) to specified torque with oil outlet union locked.

    Tightening torque 

    Oil cooler pipe union bolt a: 25 N.m (2.5 kg-m, 18.0 lb-ft) 

  4. Tighten pipe clamp bolt (3) with specified torque.

    Tightening torque 

    Pipe clamp bolt b: 10 N.m (1.0 kg-m, 7.5 lb-ft) 

    Fig 1: Identifying Pipe Clamp Bolt & Union Bolts
    G04808628Courtesy of SUZUKI OF AMERICA CORP.
  5. Check A/T fluid level according to procedure described in A/T Fluid Change.
  6. Check for fluid leakage after warming up A/T.