LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2006 >> Aerio SX, FWD, Automatic >> Repair and Diagnosis (Single Page) >> Electrical >> Charging Systems >> Diagnostic Information & Procedure >> Battery Inspection >> Load Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Load Test

  1. Connect voltmeter (1) and battery load tester (2) across battery (3) terminals.
    Fig 1: Connecting Voltmeter And Battery Load Tester Across Battery Terminals
    G04590067Courtesy of SUZUKI OF AMERICA CORP.
  2. Apply 190 ampere load for 15 seconds to remove surface charge.
  3. Remove the load and wait 15 seconds to let battery recover.
  4. Apply 190 ampere load. Read voltage after 15 seconds.
  5. Remove the load.
    • The voltage does not drop below the minimum as listed in the figure.
      • Battery is good.
    • The voltage drops below the minimum as listed in the figure.
      • Replace the battery.

Battery load test voltage 

VOLTAGE REFERENCE

Estimated temperature Minimum required voltage under 15 sec. load
21°C / 70°F 9.6 V
10°C / 50°F 9.4 V
0°C / 30°F 9.1 V
-10°C / 15°F 8.8 V
-18°C / 0°F 8.5 V
Below -18°C / 0°F 8.0 V
NOTE: Temperature of battery will affect minimum voltage required to pass load test.
See the table and estimate the temperature battery has been exposed to the last several hours.