Keyless Entry System Circuit Inspection
Check that the voltage between the following terminals and body ground are specifications under each conditions.
If check result is not as specified, check applicable circuit.
If circuit is normal, recheck keyless entry system circuit as follows.
- Substitute a known-good door lock controller and transmitter.
- Recheck keyless entry system circuit.
TERMINAL WIRE CIRCUIT CONDITION REFERENCE
| Terminal | Wire | Circuit | Specification | Condition |
|---|---|---|---|---|
| L82-4 | BLK/BLU | Interior light circuit | 10 - 14 V | Fulfill the following conditions.
|
| L82-8 | GRN/RED | Hazard warning signal circuit (left side) | Figure "A" | Push lock button on transmitter. |
| Figure "B" | Push unlock button on transmitter. | |||
| L82-9 | BLU/YEL | Hazard warning signal circuit (right side) | Figure "A" | Push lock button on transmitter. |
| Figure "B" | Push unlock button on transmitter. |