Resistance Check

WARNING: This page is about a different variant/trim than selected.

Check resistance between pressure control solenoid valve (1) terminals. If check result is not as specified, replace solenoid valve.

Pressure control solenoid valve resistance 

Standard: 5.0 - 5.6 Ω (at 20 °C (68 °F)) 

Fig 1: Checking Resistance Between Pressure Control Solenoid Valve Terminals
G04591899Courtesy of SUZUKI OF AMERICA CORP.