Automatic Stop Operation
- Connect battery positive (+) terminal to terminal "L" and its negative (-) terminal to terminal "E" and let the motor turn.
- Disconnect terminal "L" from battery positive (+) terminal, and let the motor stop.
- Connect terminals "L" and "S" with a jumper wire, and connect terminal "B" to battery positive (+) terminal. Observe the motor turns once again then stops at a specified position.
Courtesy of SUZUKI OF AMERICA CORP.
- Repeat Step 1) to 3) several times and check that the motor stops at the specified position every time. If check result is not satisfied, replace motor.