SDM Cannot Communicate Through The Serial Data Circuit: Wiring Diagram
CAUTION:
- Be sure to perform " AIR BAG DIAGNOSTIC SYSTEM CHECK " before starting diagnosis according to flow.
- When measurement of resistance or voltage is required in this flow, use a tester along with a correct terminal adapter from special tool (Connector test adapter kit).
- When a check for proper connection is required, refer to " INSPECTION OF INTERMITTENT AND POOR CONNECTIONS ".
- If there is open circuit in the air bag wire harness, connector or terminal is found damaged, replace the wire harness, connector and terminal as an assembly.
Flow Test Description
Step 1: An improper connection to the DLC will prevent communications from being established.
Step 2: This test checks whether it is possible to communicate with other control module.
Step 3: This test checks for an open in "PPL/RED" circuit.