Blower Motor Relay: Service and Repair

High-Blower Relay Removal and Installation

High-Blower Relay Removal

1. Disconnect the negative battery cable.
2. The relay is located in front of the blower motor.
3. Remove the glove box lower panel cover. Refer to Glove Box Removal.
4. Separate the relay from the connector.




5. Remove the screws with the high-blower relay.

High-Blower Relay Installation

1. Install the screws with the high blower relay.
2. Connect the electrical connector.




3. Install the glove box lower panel cover. Refer to Glove Box Installation.