Internal Wiring Harness Check
INTERNAL WIRING HARNESS VALUE CHART
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 3. | Go to Step 2. |
| 2 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 3 | Measure the resistance between terminals 3 and 13 the second solenoid valve. Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 5. | Go to Step 4. |
| 4 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 5 | Measure the resistance between terminals 5 and 6 the transaxle wiring connector (EDS 3). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 7. | Go to Step 6. |
| 6 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 7 | Measure the resistance between terminals 5 and 7 the transaxle wiring connector (EDS 4). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 9. | Go to Step 8. |
| 8 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 9 | Measure the resistance between terminals 5 and 10 the transaxle wiring connector (EDS 5). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 11. | Go to Step 10. |
| 10 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 11 | Measure the resistance between terminals 5 and 11 the transaxle wiring connector (EDS 6). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 13. | Go to Step 12. |
| 12 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 13 | Measure the resistance between terminals 4 and 9 the transaxle wiring connector (transaxle temperature sensor). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 15. | Go to Step 14. |
| 14 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 15 | Measure the resistance between terminals 15 and 16 the transaxle wiring connector (transaxle input speed sensor). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 17. | Go to Step 16. |
| 16 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 17 | Measure the resistance between terminals 1 and 2 the transaxle wiring connector (transaxle output speed sensor). Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 19. | Go to Step 18. |
| 18 |
Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | Go to Step 20. | Go to Step 22. |
| 19 | Measure the resistance between terminals of internal wiring harness. Is the resistance within the values shown? |
Refer to COMPONENT RESISTANCE CHART . | No problem found, exit table | Go to Step 21. |
| 20 | Inspect for resistance:
Check for weak terminal tension. |
- | Verify repair and Go to Step 12. | No problem found, exit table |
| 21 | Replace the internal wiring harness. Is the replacement complete. |
- | No problem found, exit table | - |
| 22 | Replace the component. Is the replacement complete. |
- | No problem found, exit table | - |