DTC Troubleshooting
DIAGNOSIS PROCEDURE - DTC P0448 EVAP VENT CONTROL CIRCUIT SHORTED
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 | Perform an On-Board Diagnostic (OBD) System Check. Is the system check complete? |
- | Go to Step 2. | Go to "ON-BOARD DIAGNOSTIC (OBD II) SYSTEM CHECK ". |
| 2 |
Do you hear or feel a click from the EVAP vent solenoid when the solenoid is commanded ON and OFF? |
- | Go to Step 3. | Go to Step 4. |
| 3 |
Did the DTC fail this ignition? |
- | Go to Step 4. | Go to "DIAGNOSTIC AIDS ". |
| 4 |
Is the voltage above the specified value? |
6.6 V | Go to Step 5. | Go to Step 6. |
| 5 | Test the control circuit of the EVAP vent solenoid for a short to voltage. Did you find and correct the condition? |
- | Go to Step 10. | Go to Step 7. |
| 6 | Test for an intermittent and for a poor connection at the EVAP vent solenoid. Did you find and correct the condition? |
- | Go to Step 10. | Go to Step 8. |
| 7 | Test for an intermittent and for a poor connection at the control module. Did you find and correct the condition? |
- | Go to Step 10. | Go to Step 9. |
| 8 | Replace the EVAP vent solenoid. Did you complete the replacement? |
- | Go to Step 10. | - |
| 9 | Replace the control module. Did you complete the replacement? |
- | Go to Step 10. | - |
| 10 |
Did the DTC fail this ignition? |
- | Go to Step 2. | Go to Step 11. |
| 11 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? |
- | Go to applicable DTC TABLE . | System OK |