DTC Troubleshooting
DIAGNOSIS PROCEDURE - DTC P0154 HO2S BANK 2 SENSOR 1 NO ACTIVITY DETECTED
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 | Perform an On-Board Diagnostic (OBD) System Check. Is the system check complete? |
- | Go to Step 2. | Go to "ON-BOARD DIAGNOSTIC (OBD II) SYSTEM CHECK ". |
| 2 |
Does the scan tool the indicate Closed Loop? |
80 °C (176 °F) 1,200 rpm | Go to Step 3. | Go to Step 4. |
| 3 |
Does the scan tool the indicate Closed Loop? |
- | Go to Step 12. | Go to Step 4. |
| 4 | Disconnect the Heated 02 sensor connector and jumper the Heated 02 sensor low circuit, terminal 4 to ground. Is the H02 voltage below the specified value and does the scan tool indicate the heated oxygen sensor heater voltage within the specified value? |
0.5 V | Go to Step 5. | Go to Step 6. |
| 5 | Check the Heated 02 sensor connector for malfunction terminals or poor connection and repair as necessary. Is repair necessary? |
- | Go to Step 12. | Go to Step 9. |
| 6 |
Does the Heated 02 sensor voltage measure above the specified value? |
0.6 V | Go to Step 10. | Go to Step 9. |
| 7 | Does the Heated 02 sensor voltage measure below the specified value? | 0.3 V | Go to Step 11. | Go to Step 8. |
| 8 | Check the Heated O2 sensor ground circuit, terminal 4 for an open or poor connection and repair as necessary. Is repair necessary? |
- | Go to Step 12. | Go to Step 8. |
| 9 | Check the Heated 02 sensor signal circuit, terminal 3 for an open or poor connection and repair as necessary. Is repair necessary? |
- | Go to Step 12. | Go to Step 8. |
| 10 |
Does the scan tool indicated that this diagnostic has run and passed? |
- | Go to Step 13. | Go to Step 2. |
| 11 |
Is the replacement complete? |
- | Go to Step 15. | - |
| 12 |
Is the replacement complete? |
- | Go to Step 15. | - |
| 13 | Check if any additional DTCs are set. Are any DTCs displaced that have not been diagnosed? |
- | Go to applicable DTC TABLE . | System OK |