DTC Troubleshooting
DIAGNOSIS PROCEDURE - DTC P0107 MANIFOLD ABSOLUTE PRESSURE SENSOR LOW INPUT
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 | Perform an On-Board Diagnostic (OBD) System Check. Is the system check complete? |
- | Go to Step 2. | Go to "ON-BOARD DIAGNOSTIC (OBD II) SYSTEM CHECK ". |
| 2 |
Does the scan tool show the manifold absolute pressure (MAP) sensor voltage below the value specified? |
4.1 V | Go to Step 3. | Go to Step 4. |
| 3 |
Does the scan tool show the MAP sensor voltage within the value specified? |
1.0 - 1.5V | Go to "DIAGNOSTIC AIDS " | Go to Step 4. |
| 4 |
Does the voltage measure within the value specified? |
4.5 - 5.5 V | Go to Step 5. | Go to Step 6. |
| 5 | Connect a fused jumper between the MAP sensor connector terminals B and C. Does the scan tool show the MAP sensor voltage above the value specified? |
4.5 V | Go to Step 13. | Go to Step 11. |
| 6 | Measure the voltage between the MAP sensor connector terminal A and ground. Does the voltage measure within the value specified? |
4.5 - 5.5 V | Go to Step 7. | Go to Step 8. |
| 7 |
Is the problem found? |
- | Go to Step 8. | Go to Step 9. |
| 8 |
Is the repair complete? |
- | System OK | - |
| 9 |
Is the problem found? |
- | Go to Step 10. | Go to Step 11. |
| 10 |
Is the repair complete? |
- | System OK | - |
| 11 | Check for an open or short to ground in the wire between the MAP sensor connector terminal B and the ECM connector terminal 12. Is the problem found? |
- | Go to Step 12. | Go to Step 14. |
| 12 |
Is the repair complete? |
- | System OK | - |
| 13 |
Is the repair complete? |
- | System OK | - |
| 14 |
Is the repair complete? |
- | System OK | - |