Air Delivery Improper
WARNING: This page is about a different car, the 2008 Suzuki Swift +, 2008 Pontiac Wave, and 2008 Chevrolet Aveo. However, it is still accessible from the selected car via links, so may be relevant.
This procedure provides a test of all functions of the heater/defroster unit.
- Warm up the vehicle.
- Keep the engine running.
- Perform the tests outlined in the table below and look for the results indicated.
| Mode Knob | Temperature Control | Blower Motor Switch | Blower Speed | Power Vent Outlet | Floor Outlet | Defrost Outlet | Side Window Outlet |
|---|---|---|---|---|---|---|---|
| Vent | Cold | OFF | OFF | No Airflow | No Airflow | No Airflow | No Airflow |
| Vent | Cold | 4 | High | Ambient Airflow | No Airflow | No Airflow | No Airflow |
| Floor | Cold to Hot | 4 | High | No Airflow | Cold to Hot Airflow | Minimum Cold to Hot Airflow | Minimum Cold to Hot Airflow |
| Defroster | Cold to Hot | 4 | High | No Airflow | Minimum Cold to Hot Airflow | Cold to Hot Airflow | Minimum Cold to Hot Airflow |
If any of these settings do not produce the correct results, perform the Improper Air Delivery diagnostic procedure.
Air Delivery Improper
| Step | Action | Yes | No |
|---|---|---|---|
| 1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle |
| 2 | Examine the affected door in the unit for proper cable attachment.
Is everything connected properly? |
Go to Step 4 | Go to Step 3 |
| 3 | Repair, as necessary. Is the repair complete? |
System OK | - |
| 4 |
|
Go to Step 5 | Go to Step 3 |
| 5 | Inspect the travel of the Bowden cable by turning the control knob. Is the actuator travel OK? |
Go to Step 6 | Go to Step 7 |
| 6 |
|
System OK | Go to Step 9 |
| 7 |
|
Go to Step 8 | Go to Step 9 |
| 8 | Repair the cable attachment or control as necessary. Is the repair complete? |
System OK | Go to Step 9 |
| 9 | Inspect the system using the Control Settings/Correct Results tests in this procedure. Is the repair complete? |
System OK | Go to Step 10 |
| 10 | Inspect for airflow from the defroster or the vent outlets. Is there high airflow from the defroster or the vent outlets? |
Go to Step 11 | Go to Step 12 |
| 11 | Adjust the heater door at the floor and the vent door to get the proper airflow. Is the repair complete? |
System OK | - |
| 12 | Switch the mode knob to defrost. Is the defroster airflow OK? |
Go to Step 13 | Go to Step 14 |
| 13 |
|
System OK | - |
| 14 | Inspect the blower speeds for change in the airflow. Does the blower speed increase as the control is turned from 1 to 4? |
Go to Step 15 | Go to Blower Motor Malfunction |
| 15 |
|
System OK | Go to Step 16 |
| 16 |
|
Go to Step 17 | Go to Step 18 |
| 17 |
|
System OK | - |
| 18 |
|
System OK | - |