DTC P0446 Evaporative Emission System Vent Control Malfunction: Troubleshooting
TROUBLESHOOTING CHART
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 | Perform an On-Board Diagnostic (OBD II) System Check. Is the system check complete? |
- | Go to Step 2 | Go to "ON-BOARD DIAGNOSTIC (OBD II) SYSTEM CHECK :" |
| 2 |
Is DTC P0452 or P0453 also set? |
- | Go to APPLICABLE DTC TABLE | Go to Step 3 |
| 3 | Command the Evaporative Emission (EVAP) Canister Purge Valve and Vent Solenoid ON and OFF with the scan tool. Does the Purge Valve and Vent Solenoid click ON and OFF? |
- | Go to Step 4 | - |
| 4 |
Is the Fuel Tank Pressure at the specified value? |
0 in. Hg | Go to Step 5 | Go to "EVAP CONTROL SYSTEM DIAGNOSIS :" |
| 5 |
NOTE:
Before continuing with this diagnosis, zero the EVAP Pressure and Vacuum gauges on the EVAP pressure/ purge cart J-41413. Also read the temperature variation instruction card.
|
1.24 kPa (0.37 in. Hg) | Go to Step 6 | Go to "EVAP CONTROL SYSTEM DIAGNOSIS :" |
| 6 |
Does the EVAP pressure return to the second specified value within 5 seconds? |
1.24 kPa (0.37 in. Hg) | Go to "DIAGNOSTIC AIDS :" | Go to Step 7 |
| 7 |
Is the vacuum displayed less than the second specified value? |
102 kPa (30 in. Hg) 2500 RPM | Go to Step 8 | Go to Step 10 |
| 8 |
Is the repair complete? |
- | Go to Step 11 | Go to Step 9 |
| 9 |
Is the repair complete? |
- | Go to Step 11 | - |
| 10 | Replace the EVAP canister. Is the repair complete? |
- | Go to Step 11 | - |
| 11 |
Does the EVAP pressure return to the second specified value within 5 seconds? |
1.24 kPa (0.37 in. Hg) | System OK | Go to Step 2 |