LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2005 >> Forenza L4-2.0L >> Repair and Diagnosis >> Heating and Air Conditioning >> Blower Motor Resistor >> Service and Repair
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Blower Motor Resistor: Service and Repair

Blower Resistor

Removal
1. Disconnect the negative battery cable.
2. Remove the glove box.
3. Disconnect the electrical connector at the resistor.
4. Remove the mount screws from the resistor.




5. Remove the resistor from the heater/air distributor case by gently pulling the resistor downward.

Installation
1. Install the resistor into the heater/air distributor case with the screws.

Tighten: Tighten the blower motor resistor screws to 1.2 Nm (11 in. lbs.).

2. Connect the electrical connector at the resistor.
3. Connect the negative battery cable.
4. Confirm the proper performance of the blower.




5. Install the glove box.