LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2005 >> Aerio S, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Automatic Transmission) >> Repair Instructions >> Pressure Control Solenoid Valve Inspection >> Resistance Check
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Resistance Check

WARNING: This page is about a different variant/trim than selected.

Check resistance between pressure control solenoid valve (1) terminals. If check result is not as specified, replace solenoid valve.

Pressure control solenoid valve resistance 

Standard: 5.0 - 5.6 Ω (at 20°C (68°F)) 

Fig 1: Checking Resistance Between Pressure Control Solenoid Valve Terminals
G04015028Courtesy of SUZUKI OF AMERICA CORP.