  1. Connect pressure control solenoid valve (1) to battery (2) setting the 8 - 10 W bulb (4) on the way as shown in the figure.
  2. Check for movement of valve (3) in the direction of arrow "A".
  3. Disconnect pressure control solenoid valve (1) from battery (2) and check movement of valve (3) in the direction of arrow "B" as shown in the figure.
CAUTION: Set 8 - 10 W bulb on the way, or pressure control solenoid valve is burned out.
Fig 1: Checking Movement Of Valve