Operation of Shift Solenoid Valves and TCC Solenoid Valve
OPERATION OF SHIFT SOLENOID VALVES AND TCC SOLENOID VALVE
| Range | D | 2 | L | R | P & N | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Gear | 1st | 2nd | 3rd | 4th | 1st | 2nd | 3rd | 1st | 2nd | Rev | - | |
| Solenoids | Shift solenoid valve-A (No. 1) | x | x | x | x | x | x | |||||
| Shift solenoid valve-B (No. 2) | x | x | x | |||||||||
| TCC solenoid valve | x | x | x | ( ) | x | x | x | x | x | x | x | |
| : ON (Turn power on) | ||||||||||||
| x: OFF (Turn power off) | ||||||||||||
| ( ): ON only when lock-up function operates | ||||||||||||
VALVE SPECIFICATION
| Valve status | ||
|---|---|---|
| Turn power ON | Turn power OFF | |
| Shift solenoid valve-A (No. 1) | Open | Close |
| Shift solenoid valve-B (No. 2) | Open | Close |
| TCC solenoid valve | Close | Open |