Fail-Safe Table

When any of the following malfunctions (DTCs) is detected, fail-safe mode is activated.

However, when HVAC control module detects normal operation of A/C system, fail-safe mode is canceled.

DTC FAIL-SAFE TABLE CHART

DTC No. Trouble Area Fail-Safe Operation
Detection of malfunction when ignition switch is turned ON Detection of malfunction during ignition switch is ON
B1501 Outside air temperature sensor and/or its circuit 20°C (68 °F) HVAC control module keeps condition just before detection.
B1502 Inside air temperature sensor and/or its circuit 25 °C (77°F)
B1503 A/C evaporator outlet temperature sensor 0 °C (32 °F)
B1504 Sunload sensor and/or its circuit 175 W/m2
B1510 Water temperature sensor and/or its circuit 80°C(176°F)
B1511 Temperature control actuator (position sensor) and/or its circuit The operation of actuator stops.
B1512 Air flow control actuator (position sensor) and/or its circuit
B1513 Temperature control actuator and/or its circuit
B1514 Air flow control actuator and/or its circuit
B1520 Temperature selector and/or its circuit 23 °C (73 °F)
B1521 Blower speed selector and/or its circuit 1st
B1522 Air flow selector and/or its circuit DEF
NOTE: In case that all of temperature selector, blower speed selector, and air flow selector are abnormal, the operation of air conditioning system stops.