Manual Selector Assembly Components: Installation
Reverse removal procedure to install manual selector assembly noting the following instructions.
- Make sure that select cable clip (3) holds select cable (1) on manual selector assembly (2) securely.
- Tighten manual selector assembly mounting bolts to specified torque.
Tightening torque
- Manual selector assembly mounting bolt: 18 N.m (1.8 kg-m, 13.5 lb-ft)