Conditions for Running
- The barometric pressure (BARO) is more than 72 kPa.
- The engine coolant temperature (ECT) at start-up is more than -5°C (23°F).
- The intake air temperature (IAT) at start-up is less than 40°C (104°F).
- The start-up IAT minus the actual IAT are within 3°C (5°F).
- The engine is OFF for more than 6 hours or the following conditions must be met:
- The start-up IAT minus start-up ECT are within 12°C (22°F).
- The start-up ECT minus start-up IAT are within 50°C (90°F).
- The ignition 1 voltage is between 10-16 volts.
- The fuel level is between 1/4 and 3/4.