Circuit Description
The engine control module (ECM) supplies a voltage near 450 mV between the heated oxygen sensor (HO2S) high signal circuit and the low reference circuit. The HO2S varies the voltage over a range from about 1,000 mV when the exhaust is rich, down through about 10 mV when the exhaust is lean.
The ECM monitors and stores the HO2S voltage information. The ECM evaluates the HO2S voltage samples in order to determine the amount of time that the HO2S voltage was out of range. The ECM compares the stored HO2S voltage samples taken within each sample period and determines if the majority of the samples are out of the operating range.
The ECM monitors the HO2S voltage for being fixed below a predetermined voltage. If the ECM detects the voltage is too high, this DTC sets.
The HO2S utilizes the following circuits:
- A signal circuit
- A low reference circuit
- An ignition 1 voltage circuit
- A heater control circuit