Rear Blower Motor Assembly Inspection for H27 Engine Model

  1. Check continuity between 2 terminal as shown.

    If check results are no continuity, replace rear blower motor assembly (1).

    Fig 1: Checking Continuity Between Terminals
    G00757870Courtesy of SUZUKI OF AMERICA CORP.
  2. Check for operation and current.
    1. Fix rear blower motor assembly (1) by using vise.
    2. Connect battery to rear blower motor assembly (1) as shown.
    3. Check that there is smoothly operates and no noise.
    4. Check that ammeter indicates specified current.

      If malfunction is found, replace blower motor assembly.

    Rear blower fan motor specified current at 12 V 

    1. 16 A maximum
Fig 2: Checking For Operation & Current
G00757871Courtesy of SUZUKI OF AMERICA CORP.