LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2004 >> Forenza S, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 30 (Automatic A/C Systems) >> Repair Instructions >> Air Flow Control Actuator Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Air Flow Control Actuator Inspection

WARNING: This page is about a different car, the 2004 Suzuki Aerio. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove air flow control actuator from heater and cooling unit referring to Air Flow Control Actuator Removal and Installation  .
  2. Connect air flow control actuator connector to the actuator (1).
  3. Set air flow selector of HVAC control module to DEF position with ignition switch ON, and make sure if the position of actuator level is DEF (A).
  4. Measure resistance between terminal "1" and "3".

    Air flow control actuator resistance between terminal "1" and "3" (DEF position) 

    Approximately less than 1.2 k/ohms

    Fig 1: Checking Air Flow Control Actuator Resistance (DEF Position)
    G00764219Courtesy of SUZUKI OF AMERICA CORP.
  5. Set air flow selector of HVAC control module to VENT position with ignition switch ON, and make sure if the position of actuator level is VENT (B).
  6. Measure resistance between terminal "1" and "3".

Air flow control actuator resistance between terminal "1" and "3" (VENT position) 

Approximately 4.8 - 6.0 k/ohms

Fig 2: Checking Air Flow Control Actuator Resistance (VENT Position)
G00764220Courtesy of SUZUKI OF AMERICA CORP.

If check result is not satisfactory, replace the actuator with new one.