LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2004 >> Aerio SX, AWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Overhaul - A/T >> Repair Instructions >> Pressure Control Solenoid Valve Inspection >> Resistance Check
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Resistance Check

Check resistance between pressure control solenoid valve (1) terminals. If check result is not as specified, replace solenoid valve.

Pressure control solenoid valve resistance 

Standard: 5.0 - 5.6 ohms (at 20 °C (68 °F))

Fig 1: Checking Pressure Control Solenoid Valve Resistance
G00764585Courtesy of SUZUKI OF AMERICA CORP.