Not Using SUZUKI Scan Tool
- Check A/C switch indicator lamp (6) for operation referring to HVAC Control Module Inspection
.
- Light over sunload sensor vertically with an incandescent lamp of approximately 60 W apart from about 100 mm (3.94 in.).
- Set the following selectors to the specified positions respectively.
- Temperature selector (1): Maximum cool position
- Air flow selector (2): "AUTO" position
- Blower speed selector (3): "OFF" position
- Keep A/C switch (4) and air intake switch (5) pushed at the same time, and turn ignition switch to ON position.
- Push A/C switch and air intake switch at the same time and then release them.
- Push A/C switch and air intake switch for more than 3 seconds.
Courtesy of SUZUKI OF AMERICA CORP.
- After completing the clearance, turn ignition switch to OFF position.
- Perform DTC Check
, and confirm that normal DTC is displayed on SUZUKI scan tool.