Quick Check of Refrigerant Charge Amount

The following procedure can be used for quickly checking whether the A/C system has a proper charge of refrigerant or not.

  1. Start engine and warm up to normal operating temperature (ECT more than 85 °C, 180 °F).
  2. Operate A/C at the following conditions for a few minutes.
    • Main (front) A/C switch at ON position
    • Rear A/C main switch at ON position (if equipped)
    • Front blower speed selector at max position
    • Rear blower motor switch at max position (if equipped)
    • Air flow selector at face position
    • Temperature selector at max cool position
    • Vehicle door at all open
    • Air inlet door at recirculation position
  3. Look at the sight glass (1) and compare what is observed with the symptoms listed in the table.
    Fig 1: Sight Glass Inspection Chart
    G01326840Courtesy of SUZUKI OF AMERICA CORP.
    NOTE: For specified amount of refrigerant, refer to OPERATION PROCEDURE FOR CHARGING A/C WITH REFRIGERANT  .
    Fig 2: Looking At Sight Glass
    G01326841Courtesy of SUZUKI OF AMERICA CORP.