G Sensor Inspection: Notes
- Check sensor bracket for bend.
- Connect positive cable of 12 V battery to "A" terminal of sensor and ground cable to "C" terminal. Then using voltmeter, check voltage between "B" terminal and "C" terminal.
If measured voltage is not as specified, replace sensor with bracket.