LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2003 >> Aerio GS, AWD, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating & Air Conditioning >> Air Conditioning System >> Repair Instructions >> Condenser Cooling Fan Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Condenser Cooling Fan Inspection

  1. Check condenser cooling fan motor for continuity between terminal "a" and "b" as shown. If there is no continuity, replace condenser cooling fan motor.
    Fig 1: Checking Condenser Cooling Fan Motor For Continuity Between Terminal
    G01355264Courtesy of SUZUKI OF AMERICA CORP.
  2. Connect battery to condenser cooling fan motor terminal "a" and "b" as shown in figure, then check that the condenser cooling fan motor operates smoothly.

    Reference 

    Condenser cooling fan specified current at 12V: 9 A maximum. 

    Fig 2: Connecting Battery To Condenser Cooling Fan Motor Terminal
    G01355265Courtesy of SUZUKI OF AMERICA CORP.