Diagnosis and Repair Procedure
- If engine system check has been performed, go to next step. If engine system check has not been performed, see and perform A4: ENGINE SYSTEM CHECK under SYSTEM TESTS and go to next step.
- With ignition switch OFF, disconnect EVAP canister purge valve connector. Turn ignition ON and measure voltage between EVAP canister purge valve connector C27 terminal No. 2 and ground. If voltage is not 10-14 volts, go to next step. If voltage is 10-14 volts, check if Green/Black circuit is shorted to power circuit. Repair as necessary and go to DTC CONFIRMATION TEST .