Door Knob Switch & Hazard Warning Light Circuit
- Disconnect negative battery cable. Disconnect Power Door Lock and Remote Keyless Entry (PDL/RKE) controller harness connector. Connect negative battery cable.
- Using DVOM connected to chassis ground, check for voltage at PDL/RKE controller connector terminal No. 6 (Yellow/Green wire). See Fig 1
. Reading should be 10-14 volts at all times. If 10-14 volts does not exist, check for an open or short in Yellow/Green wire between PDL/RKE connector to keyless entry relay No. 1 and keyless entry relay No. 2. See Figure
. See WIRING DIAGRAMS
. If reading indicates 10-14 volts, go to next step.
- Connect DVOM between ground and PDL/RKE controller connector terminal No. 11 (Brown/White wire). See Fig 1
. Check continuity exists with driver door knob is pulled up, and continuity does not exist when driver door knob is pushed down. If readings are as described, circuit is okay. If readings are not as described, check driver's door key switch. See DRIVERS DOOR KEY SWITCH
in COMPONENT TESTS. If driver's door key switch is okay, repair open or short in Brown/White wire as necessary. See WIRING DIAGRAMS
.
Courtesy of SUZUKI OF AMERICA CORP.